The
laboratory is generaly directed towards
research and didactics purposes, nevertheless
analyses for the needs of other units of Faculty of Chemistry, Jagiellonian University are also performed
The
laboratory classes are dedicatedto third-year chemistry
students in the framework of the Chemical Analysis
course
Apart
from that studies for master and doctoral theses
within the general subjects given below are also realised in the
Laboratory for Analytical Atomic Spectrometry.
- preparation
and evaluation of new sorbents for selective preconcentration of heavy
metal ions via flow injection technique and their subsequent
determination with the use of flame atomic absorption spectrometry technique
- plant analysis (co-operation with Institute of Plant Physiology Polish Academy of Science Krakow) and human
biological materials analysis towards heavy metals and their influence
on life functions or their toxicological and pathological aspects (in
co-operation with Collegium Medicum, Jagiellonian University)
- monitoring of technetium in environment with the ICP-MS determination (co-operation with Institute of Nuclear Physics Polish Academy of Science Krakow)
Apparatus:
- Flame atomic absorption spectrometers
|
|
AAS 3100 (Perkin Elmer)
|
Analyst 300 (Perkin Elmer)
|
- Flow injection analysis systems FIAS
400 from Perkin Elmer for hydride generation or cold vapor atomization
and on-line microcolumn preconcentration
- Atomic absorption spectrometer with electrothermal atomization
|
SpectraAA Zeeman 220 (Varian) |
- Atomic emission spectrometer with
inductively coupled plasma ICP-OES
|
Optima
2100 (Perkin Elmer) |
Chosen References:
- Comparison
of wet microwave digestion methods of plant materials for the
determination of metals by flame atomic absorption spectrometry
S. Walas, M. Wójtowicz, H. Mrowiec, W. Zegar, Intern. J.
Environ. Anal. Chem. 84 1023-1032 (2004).
- Application
of Zeolite Y to preconcentration and FI-FAAS determination of Pb, Cd,
Cu and Zn
S. Walas, E. Borowska, H. Mrowiec, Chem. Anal. (Warsaw), 50, 825-839,
(2005)
- Application
of a LIX 622 Liquid Ion-Exchanger of a Hydroxyoxime Type Immobilized
Onto Silica Gel for Flow Injection Preconcentration and FAAS
Determination of Copper
S.Walas, H. Mrowiec, M. Sadza, Chem. Anal. (Warsaw), 51, 727-737, (2006)
- Selenium
Status Indices, Laboratory Data, and Selected Biochemical Parameters in
End-Stage Renal Disease Patients
P. Zagrodzki, H. Bartoń, S. Walas, M. Fołta, T. Stompór, E.
Janusz-Grzybowska, M. Drożdż, W. Sułowicz, Biological Trace Element
Research, 116, 29-41, (2007)
- Application of a Metal Ion-Imprinted Polymer based on Salen-Cu Complex to Flow Injection Preconcentration and FAAS Determination of Copper
S. Walas, A. Tobiasz, M. Gawin, B. Trzewik, M. Strojny, H. Mrowiec, Talanta, 76, (2008) 96-101
- Changes in wheat plastid membrane properties induced by cadmium and selenium in presence/absence of 2,4-dichlorophenoxyacetic acid,
M. Filek, M. Zembala, Helinä Hartikainen, Z. Miszalski, A. Kornaś, R. Wietecha-Posłuszny, S. (P) Walas, Plant Cell Tiss Organ Cult, 96, (2009) 19-28,
- Antioxidants activities and concentration of selenium, zinc and copper in preterm and IUGR human placentas,
M. Zadrożna, M. Gawlik, B. Nowak, A. Marcinek, H. Mrowiec, S. Walas, R. Wietecha-Posłuszny, P. Zagrodzki, J. Trace Elem. Med. Biol., 23, (2009), 144-148,
- Cu(II)-Imprinted Styrene-Divinylbenzene Beads as a New Sorbent For Flow Injection-Flame Atomic Absorption Determination of Copper,
A. Tobiasz, S. Walas, B. Trzewik, P. Grzybek, M. M. Zaitz, M. Gawin, H. Mrowiec, Microchemical Journal, 93(1), (2009) 87-92,
- Preparation of a new Cd(II)-imprinted polymer and its application to determination of cadmium(II) via flow injection flame atomic absorption spectrometry,
M, Gawin, J. Konefał, B. Trzewik, S. Walas, A. Tobiasz, H. Mrowiec, E. Witek, Talanta, 80, (2010) 1305-1310,
|
|